1962851 Circuit Breaker

Schedule
8536.20.0040
Unit of Measure: EA

Add to Quote

We are currently out of stock of this item. Click the button below to add this item to the quote and receive up to date pricing and availability by email.

Add to Quote
Thread Size
0.438 inches
Actuator Function
Trip-reset
Actuator Position Designation
At pole one
Body Length
0.780 inches
Body Style
Single pole type
Body Width
0.580 inches
Bushing Length
0.359 inches
Case Material
Metal
Center To Center Distance Between Terminals Parallel To Length
0.593 inches
Circuit Protection Type
Overcurrent single location
Fragility Factor
Moderately rugged
Frequency In Hertz
400.0 single location
Inclosure Protection Type For Which Designed
Explosion resistant and moisture resistant
Internal Trip Release Configuration
Series trip single location
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 push-pull
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location and 5.0 amperes dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole I
800.0 ac single location and 800.0 dc single location
Mounting Facility Type And Quantity
1 threaded bushing with panel seal
Mounting Surface To Terminal End Distance
1.420 inches
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac single location and 28.0 dc single location
Pole Quantity
1
Reset Method
Manual
Specification Data
96906-ms26574 government standard
Storage Type
General purpose warehouse
Terminal Type And Quantity
2 tab with screw
Test Data Document
Etc.).
Thread Qty Per Inch (tpi)
32
Thread Series Designator
Un
Trip Delay Time In Seconds Per Rated Continuous Current
2 at 200 pct single location and 20 at 200 pct single location
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location
Trip Release Characteristic
Time delay single location
Trip Release Method
Thermal single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe
145.0 single location