Thread Size
0.469 inches
Actuator Function
Trip-reset
Actuator Position Designation
At pole one
Body Length
0.750 inches
Body Style
Single pole type
Body Width
0.562 inches
Bushing Length
0.250 inches
Case Material
Metal
Center To Center Distance Between Terminals Parallel To Length
0.703 inches
Circuit Protection Type
Overcurrent single location
Frequency In Hertz
400.0 single location
Inclosure Protection Type For Which Designed
Moisture resistant and explosion resistant
Internal Trip Release Configuration
Series trip single location
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 push-pull
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac single location and 2.0 amperes dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole I
800.0 ac single location and 2000.0 dc single location
Mounting Facility Type And Quantity
1 threaded bushing
Mounting Surface To Terminal End Distance
1.812 inches
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location and 28.0 dc single location
Pole Quantity
1
Reset Method
Manual
Specification Data
96906-ms22073 government standard
Terminal Type And Quantity
2 screw
Test Data Document
Etc.).
Thread Qty Per Inch (tpi)
32
Thread Series Designator
Uns
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct single location and 20.000 at 200 pct single location
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location
Trip Release Characteristic
Time delay single location
Trip Release Method
Thermal single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Pe
145.0 single location